Back to Main CCI Site
Products - Thermocouple Wire
Vitreous Silica Braid Insulation
Vitreous Silica Braid Jacket
1600F 871C Continuous 2000F 1093C Single Reading


DESCRIPTION:
Conductor:
Thermocouple wire per ANSI MC 96.1 & ASTM E230. (Solid or stranded available)

Sizes:
#24 AWG - #16 AWG

Insulation:
Vitreous Silica braid


APPROVALS:


APPLICATIONS:
Widely used in industrial applications such as steel, aluminum and glass plants. Also used in the heat treating industry and furnace surveys.

Excellent flame retardance and resistance to elevated temperatures
Poor resistance to moisture and abrasion

Conductor
AWG/MM
Insulation
Inches/MM
Jacket
Inches/MM
Overall Diameter
Inches/MM
Ship Wt
Lbs/MF
Ship Wt
Kg/Km
24 / .51.015 / .38.015 / .38.080 x .130 / 2.0 x 3.357
22 / .64.015 / .38.015 / .38.085 x .140 / 2.2 x 3.669
20 / .81.015 / .38.015 / .38.092 x.154 / 2.3 x 3.91015
18 / 1.02.015 / .38.015 / .38.100 x .170 / 2.5 x 4.31522
16 / 1.29.015 / .38.015 / .38.111 x.192 / 2.8 x 4.92436
24(7) / .61.015 / .38.015 / .38.084 x .138 / 2.1 x 3.557
20(7) / .97.015 / .38.015 / .38.096 x .162 / 2.4 x 4.11015
16(7) / 1.47.015 / .38.015 / .38.118 x .206 / 3.0 x 5.22436

Negative conductors is color coded with a tracer per ANSI MC 96.1 and ASTM E230.
International color codes available on request.

Available in standard and special limits of error per ANSI MC 96.1, ASTM E230 and IEC 584